ZENITH RH - Firmware Release Notes Firmware for units operating in 10-24 GHz bands. Release 2.0.20.0 2024-10-11 • New features: ○ The LSP function has been extended to include the ability to shut down Ethernet port (Link down / SFP off). • Known issues: ○ FW versions 2.x.x.0 are not over-the-air compatible with older FW versions 1.x.x.0 as a consequence of the serial number system redesign. It is necessary to install the same major FW version in both units forming a microwave link. ○ In the case of FW upgrade from versions 1.0.x.0 please read and apply instructions from section Known issues for Release 1.1.1.0. *** Release 2.0.19.0 2024-07-11 • New features: ○ The LSP function has been extended to include the ability to disconnect the backup port to prevent the creation of a loop. ○ Implementation of Dual channel operation - available for ZENITH RH 11 ○ Implementation of static configuration of the SyncE synchronization source ○ Set of supported Forward Security ciphers was extended. ○ The Factory settings function has been expanded to include the option to delete only historical data (errors, alarms, graphs). • Fixed bugs: ○ The bug of displaying the modulation in the case of using an asymmetric channel and the highest ACM profile has been fixed. ○ Fixed a delay when logging into the web configuration interface ○ Fixed auto-negotiation when connecting two ZENITH RH units directly ○ Fixed several broken links in the Help, they were referring to the Login screen • Known issues: ○ FW versions 2.x.x.0 are not over-the-air compatible with older FW versions 1.x.x.0 as a consequence of the serial number system redesign. It is necessary to install the same major FW version in both units forming a microwave link. ○ In the case of FW upgrade from versions 1.0.x.0 please read and apply instructions from section Known issues for Release 1.1.1.0. *** Release 2.0.15.0 2024-02-09 • New features: ○ Factory settings ■ Factory settings now does not delete SW keys ■ Added Total purge option, which deletes all user data in the unit including all logs and SW keys ○ The Tools > Maintenance > Backup screen has been simplified and made clearer ○ The LSP function has been extended by the possibility of interconnecting ETH ports when it is activated. This function is subject to further modifications. ○ SFP module status extended • Fixed bugs: ○ If the unit is overwhelmed by requests for new connections to management, these are rejected to avoid CPU congestion of the unit ○ Fixed listing of ATU tables for various FIDs ○ Fixed the formatting of the listing on the header bar when the LSP function is enabled ○ Fixed LSP behavior after bandwidth change ○ Behavior of SNMP traps “Air capacity changed” and “LSP activated” is not correct – fixed ○ The SNMP trap "LSP activated" has been expanded to include the current state of the LSP • Known issues: ○ FW versions 2.x.x.0 are not over-the-air compatible with older FW versions 1.x.x.0 as a consequence of the serial number system redesign. It is necessary to install the same major FW version in both units forming a microwave link. ○ In the case of FW upgrade from versions 1.0.x.0 please read and apply instructions from section Known issues for Release 1.1.1.0. *** Release 2.0.14.0 2023-12-07 • New features: ○ Support for 2.5 Gb/s metallic SFP (2500 Base-T) ○ New Link State Propagation (LSP) functionality. LSP disables user data transmission when the link speed drops below the preset threshold. ○ Remote unit management is now accessible also via Local unit management IP using port forward- ing. It is useful in situations when internal switch configuration does not enable access to the Remote unit IP (e.g. when two ETH ports are completely separated in order to serve different customers). ○ Faster ATPC reaction (better adaptation to sudden weather changes) ○ TX mute (possibility to suppress radio transmission) ○ Default WiFi channels are 5 and 9 (different for L and U unit) • Fixed bugs: ○ Minor SW fixes and improvements (SNMP alarm) ○ Minor web interface fixes • Known issues: ○ FW versions 2.x.x.0 are not over-the-air compatible with older FW versions 1.x.x.0 as a consequence of the serial number system redesign. It is necessary to install the same major FW version in both units forming a microwave link. ○ In the case of FW upgrade from versions 1.0.x.0 please read and apply instructions from section Known issues for Release 1.1.1.0. *** Release 2.0.11.0 2023-03-27 • New features: ○ Minor web interface improvements (new parameter ‘Max TX Power’, splitting ‘Current Tx Modulation’ and ‘Max Tx Modulation’ into 2 lines on the ‘Status’ page, etc.) • Fixed bugs: ○ Eliminated non-functional button for storing differential unit configuration backup ○ Minor SW fixes and improvements (MSE trap, asymmetry, modulations in rare situations, details) ○ Minor web interface fixes • Known issues: ○ FW versions 2.x.x.0 are not over-the-air compatible with older FW versions 1.x.x.0 as a consequence of the serial number system redesign. It is necessary to install the same major FW version in both units forming a microwave link. ○ After FW upgrade from versions 1.0.19.0 and earlier unit time has to be checked and manually corrected (may be wrong if time zones were used). ○ After FW upgrade from versions 1.0.16.0 and earlier it is strongly recommended to set 'FlowControl receive' for port 'Air (p9)' to value 'on' ('Show Defaults' + 'Apply' in menu 'Switch settings / Interface / Port'). It improves an utilization of Ethernet switch buffers and allows higher throughput of the link for real traffic. *** Release 2.0.9.0 2022-07-25 • New features: ○ Backward compatibility of Frequency tables • Fixed bugs: ○ Minor SW fixes and improvements ○ Minor web interface fixes and improvements • Known issues: ○ FW versions 2.x.x.0 are not over-the-air compatible with older FW versions 1.x.x.0 as a consequence of the serial number system redesign. It is necessary to install the same major FW version in both units forming a microwave link. ○ The differential external configuration backup ('Backup to external file / Difference') does not work correctly. The full external configuration backup ('Backup to external file / Full') works perfectly. ○ After FW upgrade from versions 1.0.19.0 and earlier unit time has to be checked and manually corrected (may be wrong if time zones were used). ○ After FW upgrade from versions 1.0.16.0 and earlier it is strongly recommended to set 'FlowControl receive' for port 'Air (p9)' to value 'on' ('Show Defaults' + 'Apply' in menu 'Switch settings / Interface / Port'). It improves an utilization of Ethernet switch buffers and allows higher throughput of the link for real traffic. *** Release 2.0.6.0 - only for units produced between Jun 26 and July 25, 2022 2022-06-21 • New features: ○ Frequency tables (files rcinfo….) structure extended (to support all future bands) ○ New Zabbix templates v.6.0 • Fixed bugs: ○ New driver for gyro-sensor (stability improvement) ○ Radio loopback - lowering the limit for “Good quality” from 50 to 45 dB ○ Minor SW fixes and improvements (related mainly to ZENITH R H 18GHz) ○ Minor web interface fixes and improvements • Known issues: ○ Before FW update to the version 2.0.6.0 it is necessary to update the unit to the FW version 2.0.3.0 and then activate the latest version of frequency tables (see menu Tools > Maintenance > Radio adaptation > Frequency tables). ○ FW versions 2.x.x.0 are not over-the-air compatible with older FW versions 1.x.x.0 as a consequence of the serial number system redesign. It is necessary to install the same major FW version in both units forming a microwave link. ○ The differential external configuration backup ('Backup to external file / Difference') does not work correctly. The full external configuration backup ('Backup to external file / Full') works perfectly. ○ After FW upgrade from versions 1.0.19.0 and earlier unit time has to be checked and manually corrected (may be wrong if time zones were used). ○ After FW upgrade from versions 1.0.16.0 and earlier it is strongly recommended to set 'FlowControl receive' for port 'Air (p9)' to value 'on' ('Show Defaults' + 'Apply' in menu 'Switch settings / Interface / Port'). It improves an utilization of Ethernet switch buffers and allows higher throughput of the link for real traffic. *** Release 2.0.3.0 2022-04-04 • New features: ○ Support for new USB/WiFi adapter ○ Diagnostic package content extended ○ Improved help (new internal structure) • Fixed bugs: ○ Antenna Alignment Tool (/tk) - indication of ACM readiness for antenna alignment (green = ACM off, red = ACM on) ○ Minor SW fixes and improvements (related mainly to ZENITH R H 18GHz) ○ Minor web interface fixes and improvements • Known issues: ○ FW versions 2.x.x.0 are not over-the-air compatible with older FW versions 1.x.x.0 as a consequence of the serial number system redesign. It is necessary to install the same major FW version in both units forming a microwave link!!! ○ The differential external configuration backup ('Backup to external file / Difference') does not work correctly. The full external configuration backup ('Backup to external file / Full') works perfectly. ○ After FW upgrade from versions 1.0.19.0 and earlier unit time has to be checked and manually corrected (may be wrong if time zones were used). ○ After FW upgrade from versions 1.0.16.0 and earlier it is strongly recommended to set 'FlowControl receive' for port 'Air (p9)' to value 'on' ('Show Defaults' + 'Apply' in menu 'Switch settings / Interface / Port'). It improves an utilization of Ethernet switch buffers and allows higher throughput of the link for real traffic. *** Release 2.0.1.0 2021-12-03 • New features: ○ Unit serial number system is redesigned ○ ZENITH R H 18GHz support ○ Power supply voltage level is checked on system boot ○ Alarm severities are renamed (Critical → Emergency, Major → Alert, Minor → Error); see menu ‘Link settings / Alarms / Status’ • Fixed bugs: ○ Minor SW fixes and improvements • Known issues: ○ FW versions 2.x.x.0 are not over-the-air compatible with older FW versions 1.x.x.0 as a consequence of the serial number system redesign. It is necessary to install the same major FW version in both units forming a microwave link!!! ○ Changing some combinations of radio parameters on ZENITH R H 18 link takes upto 30 seconds, leads to misleading error message “Cannot connect to peer” and the Peer configuration is not displayed. Anyhow, the configuration is updated correctly and the proper Peer configuration is displayed after click on ‘Refresh’ button. ○ The differential external configuration backup ('Backup to external file / Difference') does not work correctly. The full external configuration backup ('Backup to external file / Full') works perfectly. ○ After FW upgrade from versions 1.0.19.0 and earlier unit time has to be checked and manually corrected (may be wrong if time zones were used). ○ After FW upgrade from versions 1.0.16.0 and earlier it is strongly recommended to set '!FlowControl receive' for port 'Air (p9)' to value 'on' ('Show Defaults' + 'Apply' in menu 'Switch settings / Interface / Port'). It improves an utilization of Ethernet switch buffers and allows higher throughput of the link for real traffic. *** Release 1.1.8.0 2021-11-16 • Fixed bugs: ○ New driver for gyro-sensor (stability improvement) ○ Minor SW fixes and improvements • Known issues: ○ The differential external configuration backup ('Backup to external file / Difference') does not work correctly. The full external configuration backup ('Backup to external file / Full') works perfectly. ○ After FW upgrade from versions 1.0.19.0 and earlier unit time has to be checked and manually corrected (may be wrong if time zones were used). ○ After FW upgrade from versions 1.0.16.0 and earlier it is strongly recommended to set '!FlowControl receive' for port 'Air (p9)' to value 'on' ('Show Defaults' + 'Apply' in menu 'Switch settings / Interface / Port'). It improves an utilization of Ethernet switch buffers and allows higher throughput of the link for real traffic. *** Release 1.1.5.0 2021-09-23 • New features: ○ Added item “Power to be received” (for possible user input of expected strength of received signal) ○ Security libraries update (including library for GUI) • Fixed bugs: ○ Minor internal SW fixes and improvements ○ Minor web interface fixes and improvements • Known issues: ○ The differential external configuration backup ('Backup to external file / Difference') does not work correctly. The full external configuration backup ('Backup to external file / Full') works perfectly. ○ After FW upgrade from versions 1.0.19.0 and earlier unit time has to be checked and manually corrected (may be wrong if time zones were used). ○ After FW upgrade from versions 1.0.16.0 and earlier it is strongly recommended to set '!FlowControl receive' for port 'Air (p9)' to value 'on' ('Show Defaults' + 'Apply' in menu 'Switch settings / Interface / Port'). It improves an utilization of Ethernet switch buffers and allows higher throughput of the link for real traffic. *** Release 1.1.3.0 2021-01-29 New features: AES Encryption of user traffic (new menu 'Link settings / Radio / Encryption') Radio loopback (new menu 'Tools / Live data / Radio loopback') Fixed bugs: Provider Bridge switch configuration (menu 'Switch / Advanced / VTU') Minor internal SW fixes and improvements Known issues: The differential external configuration backup ('Backup to external file / Difference') does not work correctly. The full external configuration backup ('Backup to external file / Full') works perfectly After FW upgrade from versions 1.0.19.0 and earlier unit time has to be checked and manually corrected (may be wrong if time zones were used) After FW upgrade from versions 1.0.16.0 and earlier it is strongly recommended to set '!FlowControl receive' for port 'Air (p9)' to value 'on' ('Show Defaults' + 'Apply' in menu 'Switch settings / Interface / Port'). It improves an utilization of Ethernet switch buffers and allows higher throughput of the link for real traffic *** Release 1.1.1.0 2020-09-29 New features: Ethernet switch - Quality of Service is fully configurable (new menu 'Switch settings / QoS') Security libraries update Fixed bugs: Calculation of BER values, BER graphs Minor internal SW fixes and improvements Known issues: The differential external configuration backup ('Backup to external file / Difference') does not work correctly. The full external configuration backup ('Backup to external file / Full') works perfectly After FW upgrade from versions 1.0.19.0 and earlier unit time has to be checked and manually corrected (may be wrong if time zones were used) After FW upgrade from versions 1.0.16.0 and earlier it is strongly recommended to set '!FlowControl receive' for port 'Air (p9)' to value 'on' ('Show Defaults' + 'Apply' in menu 'Switch settings / Interface / Port'). It improves an utilization of Ethernet switch buffers and allows higher throughput of the link for real traffic *** Release 1.0.22.0 2020-06-18 Notice: Time should be checked and manually corrected after FW upgrade from versions 1.0.19.0 and earlier (may be wrong if time zones were used) New features: Support for new USB/ETH adapter AXAGON ADE-XR Fixed bugs: Minor internal SW fixes and improvements Known issues: Graph BER shows more than 3 orders of magnitude higher error rate than the reality is. Occasional reboots looks to be finally solved already in FW version 1.0.21.0. If any unexpected reboot, strange behavior or other incident occurs, please please contact Technical support on http://www.al-wireless.com/helpdesk-form-3. The differential external configuration backup (Backup to external file / Difference) does not work correctly. The full external configuration backup (Backup to external file / Full) works perfectly. After FW upgrade from FW versions 1.0.16.0 and older it is strongly recommended to set '!FlowControl receive' for port 'Air (p9)' to value 'on' (Show Defaults + Apply in menu Switch settings / Interface / Port). It improves an utilization of Ethernet switch buffers and allows higher throughput of the link for real traffic. *** Release 1.0.21.0 2020-04-22 Notice: Time should be checked and manually corrected after FW upgrade from versions 1.0.19.0 and earlier (may be wrong if time zones were used) New features: Added locks for more secure communication in the unit kernel Kernel and watchdog monitoring and logging extended Fixed bugs: Improved driver of internal system SPI bus (originally third-party SW piece) Known issues: Occasional reboots looks to be finally solved in this version (by 2 improvements above, which should address the source of the issue). If any unexpected reboot, strange behavior or other incident occurs, please contact Technical support on http://www.al-wireless.com/helpdesk-form-3. The differential external configuration backup (Backup to external file / Difference) does not work correctly. The full external configuration backup (Backup to external file / Full) works perfectly. After FW upgrade from FW versions 1.0.16.0 and older it is strongly recommended to set '!FlowControl receive' for port 'Air (p9)' to value 'on' (Show Defaults + Apply in menu Switch settings / Interface / Port). It improves an utilization of Ethernet switch buffers and allows higher throughput of the link for real traffic. *** Release 1.0.20.0 March 2020 Notice: Time should be checked and manually corrected after FW upgrade (time may be wrong if time zones were used) New features: Higher password strength (length 5-80 bytes, wider set of password characters - UTF-8) Improved behavior after short link disconnection Removed feature: RSTP root bridge (pages 'Switch settings / Status / RSTP' and 'Switch settings / Advanced / RSTP') Fixed bugs: Time settings and handling Occasional ACM freezing on low modulations Minor web interface fixes and improvements (graph axis, Flow control ...) Known issues: Occasional reboots may still happen in a very small percentage of links. In such a case please run the CLI command "cli_wdog_holdon -b" (in CLI or in box Command on the page Tools/Programs/CLI) on both sides of the link. This command prevents spontaneous reboots and starts to log internal system watchdogs (the reason for reboots). Then please contact Technical support on http://www.al-wireless.com/helpdesk-form-3. The differential external configuration backup (Backup to external file / Difference) does not work correctly. The full external configuration backup (Backup to external file / Full) works perfectly. After FW upgrade from FW versions 1.0.16.0 and older it is recommended to set '!FlowControl receive' for port 'Air (p9)' to value 'on' (Show Defaults + Apply in menu Switch settings / Interface / Port). It improves utilization of Ethernet switch buffers and allows higher throughput of the link for real traffic.